ComRead() 
Retrieves information from a serial device.
Syntax
ComRead([<cName>], [<nReceive>],
[<cTerminator>], [<nTimeout>]) -->
cReceiveString
Arguments
<cName> --> The optional name of the
communications device to configure.
If you intend to open more than one serial
communications device then you must specify a communications device
name, e.g, "Weight Scale", "Cash Register", "Modem", "Serial Port
4", etc., in order to allow CAPITAL to distinguish between
them.
<nReceive> --> An
optional number of characters to receive.
<cTerminator> -->
The character code to optionally wait for, which will terminate the
read process.
<nTimeOut> --> An
optional number of seconds to wait before the reading process is
considered complete. If not specified the default wait period is 5
seconds.
Returns
The result of the read process returned as a
character string value.
Description
Reads information from a serial communications
device.
You must first set-up and open a communications device
before you may write information to it, using the
ComOpen() or
ComSetup()
functions.
Example
If ComOpen("My Device
1")
If
ComWrite("My Device1 ", "Hello")
cResponse :=
ComRead("My Device")
Endif
ComClose("My Device")
Endif